Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Oral Rehabil ; 51(4): 724-732, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38151857

RESUMEN

BACKGROUND: The impact of treatments on completely edentulous individuals on masticatory performance (MP), oral health-related quality of life (OHRQoL), nutritional status (NS) and socio-economic profile (SP) is unclear in the literature. OBJECTIVE: To compare the MP, OHRQoL, NS and SP of totally edentulous elderly users of bimaxillary complete dentures (CD) and users of lower implant-supported fixed complete dentures (IFCD). METHODS: Forty participants were allocated into groups according to rehabilitation treatment (n = 20): bimaxillary CD (G1) and lower IFCD, and upper CD (G2). The evaluation of MP used almonds by the method of sieves. Four questionnaires (Geriatric Oral Health Assessment Index-GOHAI and Oral Health Impact Profile Edent-OHIP-Edent, Brazilian Economic Classification Criteria-ABEP and Mini Nutritional Assessment-MNA) were applied to assess the OHRQoL, SP and NS of the elderly, respectively. After evaluating the statistical assumptions, the Mann-Whitney (α = .05) test was applied to compare the groups regarding MP, OHRQoL, NS and SP. Spearman's correlation (α = .05) was performed to verify the correlation between the MP, the OHRQoL and the NS of the participants. RESULTS: G2 showed better MP (p < .05) in all masticatory cycles, OHRQoL (p < .05) and NS than the G1. However, the participants' self-perception of oral health did not differ between groups (p < .05). A moderate negative correlation was found between MP and OHRQoL for 40 masticatory cycles (r2 = -0.513; p = .001). CONCLUSION: Individuals rehabilitated with IFCD had a higher average monthly family income and achieved superior behaviour in MP and OHRQoL, in addition to lower risks of malnutrition when compared to individuals using bimaxillary CD.


Asunto(s)
Boca Edéntula , Estado Nutricional , Anciano , Humanos , Estudios Transversales , Salud Bucal , Calidad de Vida
2.
PLoS One ; 18(10): e0292430, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37792886

RESUMEN

This study evaluated surface properties and adhesion/biofilm formation by Candida albicans on 3D printed denture base resins used in 3D printing. Disc-shaped specimens (15 mm x 3 mm) of two 3D-printed resins (NextDent Denture 3D+, NE, n = 64; and Cosmos Denture, CO, n = 64) and a heat-polymerized resin (Lucitone 550, LU, control, n = 64) were analyzed for surface roughness (Ra µm) and surface free energy (erg cm-2). Microbiologic assays (90-min adhesion and 48-h biofilm formation by C. albicans) were performed five times in triplicate, with the evaluation of the specimens' surface for: (i) colony forming units count (CFU/mL), (ii) cellular metabolism (XTT assay), and (iii) fluorescence and thickness of biofilm layers (confocal laser scanning microscopy). Data were analyzed using parametric and nonparametric tests (α = 0.05). LU presented higher surface roughness Ra (0.329±0.076 µm) than NE (0.295±0.056 µm) (p = 0.024), but both were similar to CO (0.315±0.058 µm) (p = 1.000 and p = 0.129, respectively). LU showed lower surface free energy (47.47±2.01 erg cm-2) than CO (49.61±1.88 erg cm-2) and NE (49.23±2.16 erg cm-2) (p<0.001 for both). The CO and NE resins showed greater cellular metabolism (p<0.001) and CO only, showed greater colonization (p = 0.015) by C. albicans than LU in the 90-min and 48-hour periods. It can be concluded that both 3D-printed denture base resins are more prone to colonization by C. albicans, and that their surface free energy may be more likely associated with that colonization than their surface roughness.


Asunto(s)
Candida albicans , Bases para Dentadura , Bases para Dentadura/microbiología , Biopelículas , Propiedades de Superficie , Impresión Tridimensional , Ensayo de Materiales , Polimetil Metacrilato
4.
J Appl Oral Sci ; 31: e20230104, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37466551

RESUMEN

BACKGROUND: The formation of biofilm on denture bases is a recurrent clinical problem that favors the development of denture stomatitis. The effectiveness of a hygiene protocol in a 3D-printed denture base resin is still uncertain. OBJECTIVE: To evaluate of the effectiveness of immersion, associated or not with brushing in a soap solution, on the biofilm control of a 3D-printed denture base resin. METHODOLOGY: Specimens of denture base resins [Cosmos Denture (COS) and Classico (CLA/control)] were contaminated in vitro with Candida albicans and immersed in sodium hypochlorite 0.25% (SH, alkaline peroxide) AP, chlorhexidine digluconate 2% (CD or PBS-Control), associated or not with brushing with 0.78% Lifebuoy soap. Roughness was evaluated before and after brushing and immersion. The effectiveness of the protocols was assessed by CFU/mL, cellular metabolism (XTT), scanning electron microscopy (SEM), and confocal scanning laser microscopy. Data were analyzed by T student, ANOVA/Welch, and Tukey/Gomes-Howell pos-hoc tests (α = 0.05). RESULTS: CLA showed greater roughness than COS. CFU/mL and XTT were higher in COS resin with a higher hyphae formation. Immersion in SH and CD eliminated CFU/mL and reduced XTT for both resins, associated or not with brushing. AP reduced CFU/mL only when associated with brushing. CONCLUSIONS: The biofilm on the 3D-printed resin was thicker and presumably more pathogenic, regardless of its smoother surface. Immersions in SH 0.25% and CD 2% are effective hygiene protocols for both resins, associated or not with brushing. AP should be recommended when associated with brushing with a Lifebuoy 0.78% solution.


Asunto(s)
Desinfectantes , Humanos , Bases para Dentadura , Candida albicans , Biopelículas , Impresión Tridimensional , Propiedades de Superficie , Ensayo de Materiales
5.
J. appl. oral sci ; 31: e20230104, 2023. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1448550

RESUMEN

Abstract The formation of biofilm on denture bases is a recurrent clinical problem that favors the development of denture stomatitis. The effectiveness of a hygiene protocol in a 3D-printed denture base resin is still uncertain. Objective To evaluate of the effectiveness of immersion, associated or not with brushing in a soap solution, on the biofilm control of a 3D-printed denture base resin. Methodology Specimens of denture base resins [Cosmos Denture (COS) and Classico (CLA/control)] were contaminated in vitro with Candida albicans and immersed in sodium hypochlorite 0.25% (SH, alkaline peroxide) AP, chlorhexidine digluconate 2% (CD or PBS-Control), associated or not with brushing with 0.78% Lifebuoy soap. Roughness was evaluated before and after brushing and immersion. The effectiveness of the protocols was assessed by CFU/mL, cellular metabolism (XTT), scanning electron microscopy (SEM), and confocal scanning laser microscopy. Data were analyzed by T student, ANOVA/Welch, and Tukey/Gomes-Howell pos-hoc tests (α = 0.05). Results CLA showed greater roughness than COS. CFU/mL and XTT were higher in COS resin with a higher hyphae formation. Immersion in SH and CD eliminated CFU/mL and reduced XTT for both resins, associated or not with brushing. AP reduced CFU/mL only when associated with brushing. Conclusions The biofilm on the 3D-printed resin was thicker and presumably more pathogenic, regardless of its smoother surface. Immersions in SH 0.25% and CD 2% are effective hygiene protocols for both resins, associated or not with brushing. AP should be recommended when associated with brushing with a Lifebuoy 0.78% solution.

6.
J Adv Prosthodont ; 14(5): 305-314, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36452364

RESUMEN

PURPOSE: The aim of this study was to evaluate the flexural strength of a 3D-printed denture base resin (Cosmos Denture), after different immediate repair techniques with surface treatments and thermocycling. MATERIALS AND METHODS: Rectangular 3D-printed denture base resin (Cosmos Denture) specimens (N = 130) were thermocycled (5,000 cycles, 5℃ and 55℃) before and after the different repair techniques (n = 10 per group) using an autopolymerized acrylic resin (Jet, J) or a hard relining resin (Soft Confort, SC), and different surface treatments: Jet resin monomer for 180 s (MMA), blasting with aluminum oxide (JAT) or erbium: yttrium-aluminum-garnet laser (L). The control group were intact specimens. A three-point flexural strength test was performed, and data (MPa) were analyzed by ANOVA and Games-Howell post hoc test (α = 0.05). Each failure was observed and classified through stereomicroscope images and the surface treatments were viewed by scanning electron microscope (SEM). RESULTS: Control group showed the highest mean of flexural strength, statistically different from the other groups (P < .001), followed by MMA+J group. The groups with L treatment were statistically similar to the MMA groups (P > .05). The JAT+J group was better than the SC and JAT+SC groups (P < .05), but similar to the other groups (P > .05). Adhesive failures were most observed in JAT groups, especially when repaired with SC. The SEM images showed surface changes for all treatments, except JAT alone. CONCLUSION: Denture bases fabricated with 3D-printed resin should be preferably repaired with MMA+J. SC and JAT+SC showed the worst results. Blasting impaired the adhesion of the SC resin.

7.
J Appl Oral Sci ; 28: e20200092, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33111881

RESUMEN

BACKGROUND: The period of functional adaptation to a new conventional complete denture embraces many transitory issues, and this period is directly related to the rehabilitation success. OBJECTIVE: This clinical trial evaluated the influence of the height of mandibular ridge on the masticatory function of complete denture (CD) wearers during the adaptation period. METHODOLOGY: A total of 28 individuals wearing new CDs (NR, n=14, normal mandibular ridges, 64±12.5 years, 9 female; RR, n=14, resorbed mandibular ridges, 69±6.8 years, 9 female) were assessed at 24 hours, 30 days, three months and six months after the insertion of the CDs for masticatory performance (MP, sieves method), satisfaction with CDs (questionnaire) and maximum occlusal bite force (MOBF) (gnatodynamometer). The classification of the mandibular ridges followed the Kapur index. Data of MP and MOBF were analyzed by two-way ANOVA and satisfaction with CDs was analyzed by Generalized Estimating Equations (GEE), α=.05. RESULTS: Participants with NR presented better masticatory performance (p=.000 - NR 30.25±9.93%, RR 12.41±7.17%), general satisfaction (p=.047), retention of mandibular denture (p=.001), chewing ability (p=.037), and comfort of wearing a mandibular denture (p=.000). Regardless of the mandibular ridge, MP (p=.000) was higher at three (21.26±12.07%) and six months (24.25±12.26%) in comparison to 24 hours (18.09±10.89%), the MOBF (p=.000) was higher at three months (78.50±6.49 N) compared to 24 hours (57.34±5.55 N) and 30 days (62.72±5.97 N), and the comfort of wearing a mandibular denture (p=.002) at three months (1.61 ± 0.07) was greater than 24 hours (1.29±0.10) and 30 days (1.36±10). CONCLUSIONS: The study suggests that the participants with NR have higher MP and satisfaction with their CD, regardless of the follow-up period after the insertion of the new CD. After subjects received the CD, a period of 3 months was necessary for achieving better achievement MOBF, MP, and self-perceived comfort with the mandibular denture, regardless of the height of the mandibular ridge.


Asunto(s)
Dentadura Completa , Mandíbula/anatomía & histología , Masticación , Anciano , Fuerza de la Mordida , Oclusión Dental , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Encuestas y Cuestionarios
8.
J Prosthodont Res ; 64(3): 264-271, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31445849

RESUMEN

PURPOSE: This study evaluated the effect of the use of a powder-type adhesive on masticatory performance and oral health related quality of life (OHRQoL) in patients with normal and resorbed mandibular ridges during adaptation period with complete dentures. METHODS: Forty-two edentulous subjects (12 men, 30 women) were distributed in four groups: normal mandibular ridges with adhesive, n = 10; normal mandibular ridges without adhesive, n = 10; resorbed mandibular ridges with adhesive, n = 11; resorbed mandibular ridges without adhesive, n = 11. Masticatory performance was evaluated by sieving method and OHRQoL by Oral Health Impact Profile in Edentulous Adults (OHIP-EDENT) inventory at 30, 60 and 90 days after the insertion of new complete dentures. Data were analyzed using 2-way ANOVA test and Generalized Estimating Equations (GEEs), α = 0.05. RESULTS: The use of adhesive resulted in better masticatory performance at 30 (35.76 ± 12.63%) and 60 days (30.06 ± 10.54%) after the insertion of the dentures and did not influence on OHRQoL in participants with normal ridges during the adaptation period. The use of adhesive did not interfere on masticatory performance during adaptation period and had a negative effect on masticatory discomfort/disability subscale OHRQoL at 30-day period [5.2(3.6, 6.8)] for resorbed mandibular ridges with new complete dentures. CONCLUSIONS: The use of adhesive can improve masticatory performance of new complete dentures users with normal mandibular ridges in the initial adaptation period up to 60 days after insertion. For resorbed ridges subjects, the use of adhesive had a negative impact on masticatory discomfort/disability OHRQoL at 30 days after insertion.


Asunto(s)
Boca Edéntula , Calidad de Vida , Adulto , Cementos Dentales , Dentadura Completa , Femenino , Humanos , Masculino , Masticación
9.
J. appl. oral sci ; 28: e20200092, 2020. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1134775

RESUMEN

Abstract The period of functional adaptation to a new conventional complete denture embraces many transitory issues, and this period is directly related to the rehabilitation success. Objective This clinical trial evaluated the influence of the height of mandibular ridge on the masticatory function of complete denture (CD) wearers during the adaptation period. Methodology A total of 28 individuals wearing new CDs (NR, n=14, normal mandibular ridges, 64±12.5 years, 9 female; RR, n=14, resorbed mandibular ridges, 69±6.8 years, 9 female) were assessed at 24 hours, 30 days, three months and six months after the insertion of the CDs for masticatory performance (MP, sieves method), satisfaction with CDs (questionnaire) and maximum occlusal bite force (MOBF) (gnatodynamometer). The classification of the mandibular ridges followed the Kapur index. Data of MP and MOBF were analyzed by two-way ANOVA and satisfaction with CDs was analyzed by Generalized Estimating Equations (GEE), α=.05. Results Participants with NR presented better masticatory performance (p=.000 - NR 30.25±9.93%, RR 12.41±7.17%), general satisfaction (p=.047), retention of mandibular denture (p=.001), chewing ability (p=.037), and comfort of wearing a mandibular denture (p=.000). Regardless of the mandibular ridge, MP (p=.000) was higher at three (21.26±12.07%) and six months (24.25±12.26%) in comparison to 24 hours (18.09±10.89%), the MOBF (p=.000) was higher at three months (78.50±6.49 N) compared to 24 hours (57.34±5.55 N) and 30 days (62.72±5.97 N), and the comfort of wearing a mandibular denture (p=.002) at three months (1.61 ± 0.07) was greater than 24 hours (1.29±0.10) and 30 days (1.36±10). Conclusions The study suggests that the participants with NR have higher MP and satisfaction with their CD, regardless of the follow-up period after the insertion of the new CD. After subjects received the CD, a period of 3 months was necessary for achieving better achievement MOBF, MP, and self-perceived comfort with the mandibular denture, regardless of the height of the mandibular ridge.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Dentadura Completa , Mandíbula/anatomía & histología , Masticación , Fuerza de la Mordida , Encuestas y Cuestionarios , Satisfacción del Paciente , Oclusión Dental , Persona de Mediana Edad
10.
J Prosthodont Res ; 63(4): 421-427, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31047845

RESUMEN

PURPOSE: The present cross-over study evaluated the masticatory function and maximum occlusal force of edentulous patients with complete dentures with bilateral balanced occlusion (BBO) and canine guidance (CG), with normal (NR) and resorbed mandibular ridges (RR). METHODS: Participants received new complete dentures and both occlusal concepts (BBO and CG) were applied for a period of 30 days each. The masticatory performance was evaluated with the sieving method; masticatory ability with a visual analog scale (VAS) and maximum occlusal force was assessed by means of a gnatodynamometer. Data were analyzed using repeated-measure ANOVA or Generalized Estimating Equations (GEEs), α = 0.05. RESULTS: Thirty women completed the trial. The height of mandibular ridge was significant for the masticatory performance (ANOVA, p < 0.001, NR = 46.35 ± 12.18%, RR = 30.39 ± 9.94%), regardless of the occlusion guidance. A significant effect of the occlusion guidance was observed for the maximum occlusal force (ANOVA, p = 0.021, CG = 31.99 ± 12.74 N, BBO = 28.37 ± 9.83 N). The occlusion guidance was not significant for the masticatory performance (ANOVA, p = 0.156) and the height of the mandibular ridge did not influence on the occlusal force (ANOVA, p = 0.060). The interaction of the factors (guidance × ridge) was not significant for masticatory performance (ANOVA, p = 0.184) and occlusal force (ANOVA, p = 0.236). The VAS scores showed a significant effect of the ridge on chewing of lettuce, resulting in greater ease (GEEs, p = 0.016) and chewing quality (GEE, p = 0.028) of this food for participants with resorbed ridges. Participants with CG reported greater ease of chewing fresh bread and beef, and expressed higher quality of chew raw carrot. Participants with CG and normal ridges exhibited the highest overall chewing ability, in comparison to BBO (Bonferroni, p < 0.05, CG = 91.9, BBO = 72.7). CONCLUSIONS: CG represents a viable alternative to the BBO in complete dentures with satisfactory clinical results related to the self-perception of chewing and occlusal force.


Asunto(s)
Resorción Ósea , Oclusión Dental , Estudios Cruzados , Diseño de Dentadura , Dentadura Completa , Femenino , Humanos , Masticación
11.
J Prosthodont ; 28(7): 757-765, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29679427

RESUMEN

PURPOSE: The present randomized clinical trial compared the oral health-related quality of life (OHRQoL), peri-implant parameters, mandible movements, and maxillary complete denture movement during chewing between wearers of single- (1-IOD) and wearers of two-implant overdentures (2-IODs) for a period of 12 months. MATERIALS AND METHODS: Twenty-one complete denture wearers were randomly allocated into two parallel groups: 1-IOD (n = 11) or 2-IODs (n = 10). The validated Brazilian version of the OHIP-EDENT was used to evaluate the OHRQoL. A kinesiograph recorded maxillary complete denture movement during chewing of hard food testing (polysulphide impression material) and soft food testing (bread). Peri-implant parameters were also recorded: plaque index (PI), bleeding on probing (BOP), and probing depth (PD). The Friedman test was used to compare the OHRQoL data and peri-implant parameters among periods; the Mann-Whitney test was performed to compare the groups (1- and 2-IODs). One-way ANOVA and the Bonferroni test were used to compare mandible movement during chewing among periods, and the t-test for independent samples was used to compare the groups. Maxillary complete denture movement was analyzed using three-way ANOVA followed by the Bonferroni test. All statistical analyses were performed at α = 0.05. RESULTS: Both treatments led to better general OHRQoL in comparison to conventional complete dentures (p < 0.001). Better OHRQoL was observed among 2-IOD patients at the 12-month follow up (p = 0.034). Peri-implant parameters were similar irrespective of the group and follow-up period. Vertical opening was significantly higher among 1-IOD patients at 3 months (p = 0.038). Decreased maxillary denture vertical intrusions were observed with complete dentures in comparison with overdentures (p = 0.006), regardless of the food test (p = 0.251); however, vertical intrusion was significantly higher among 1-IOD patients (p = 0.043). CONCLUSIONS: This study suggested that 1-IOD can improve patient OHRQoL and may be similar to 2-IODs in preservation of both peri-implant parameters and masticatory movements.


Asunto(s)
Prótesis de Recubrimiento , Calidad de Vida , Brasil , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Dentadura Completa Inferior , Humanos , Mandíbula , Masticación , Salud Bucal , Satisfacción del Paciente
12.
Braz Dent J ; 29(6): 576-582, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30517481

RESUMEN

Several attachment systems for mandibular implant-supported overdentures are currently available and studies are required to understand their mechanical properties. The objective of this study was to evaluate the retention force and wear characteristics of three attachment systems in a simulation of the cyclic dislodging of implant-supported overdentures. Thirty samples were fabricated and divided into 3 groups: 1-O-ring; 2-Mini Ball; and 3-Equator. A mechanical fatigue test was applied to the specimens using a servo-hydraulic universal testing machine performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values ​​were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group was randomly selected and analyzed by scanning electron microscopy. Two-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). The O-ring system remained stable during all periods tested and exhibited significantly lower retention force values than the Mini Ball and Equator systems. The Mini Ball system exhibited a significant increase in retention force after the mechanical test (baseline=21.04±3.29N; 5500 cycles=24.01±3.30N).The Equator system exhibited a significant decrease in retention force after each period tested, but the values were higher than the other systems. The type of attachment was found to influence retention force in different ways after mechanical tests. The Equator system exhibited the highest retention force values. The Mini Ball and Equator matrices produced deformation and wear on the surfaces without breakage of the polyamide rings.


Asunto(s)
Prótesis Dental de Soporte Implantado , Ajuste de Precisión de Prótesis , Prótesis de Recubrimiento , Análisis del Estrés Dental , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Saliva Artificial , Resistencia a la Tracción
13.
Braz. dent. j ; 29(6): 576-582, Nov.-Dec. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-974198

RESUMEN

Abstract Several attachment systems for mandibular implant-supported overdentures are currently available and studies are required to understand their mechanical properties. The objective of this study was to evaluate the retention force and wear characteristics of three attachment systems in a simulation of the cyclic dislodging of implant-supported overdentures. Thirty samples were fabricated and divided into 3 groups: 1-O-ring; 2-Mini Ball; and 3-Equator. A mechanical fatigue test was applied to the specimens using a servo-hydraulic universal testing machine performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values ​​were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group was randomly selected and analyzed by scanning electron microscopy. Two-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). The O-ring system remained stable during all periods tested and exhibited significantly lower retention force values than the Mini Ball and Equator systems. The Mini Ball system exhibited a significant increase in retention force after the mechanical test (baseline=21.04±3.29N; 5500 cycles=24.01±3.30N).The Equator system exhibited a significant decrease in retention force after each period tested, but the values were higher than the other systems. The type of attachment was found to influence retention force in different ways after mechanical tests. The Equator system exhibited the highest retention force values. The Mini Ball and Equator matrices produced deformation and wear on the surfaces without breakage of the polyamide rings.


Resumo Vários sistemas de encaixe para sobredentaduras mandibulares implantossuportadas estão atualmente disponíveis e estudos são necessários para entender as suas propriedades mecânicas. O objetivo deste estudo foi avaliar a força de retenção e as características de desgaste de três sistemas de encaixe por meio de uma simulação de deslocamento cíclico de sobredentaduras implantossuportadas. Trinta amostras foram fabricadas e divididas em 3 grupos: 1-O-ring; 2-Mini Ball; e 3-Equador. Um teste de fadiga mecânica foi aplicado aos espécimes utilizando uma máquina de teste universal servo-hidráulica com 5500 ciclos de inserção/remoção (f = 0,8 Hz), imersos em saliva artificial. Os valores da força de retenção foram obtidos antes e após 1500, 3000 e 5500 ciclos utilizando uma velocidade de 1 mm/min e uma célula de carga de 1 kN. Um espécime de cada grupo foi selecionado aleatoriamente e analisado por microscopia eletrônica de varredura. O teste de Análise de Variância a dois fatores para medidas repetidas e o teste de comparações múltiplas de Bonferroni foram utilizados para análises estatísticas (α = 0,05). O sistema de O-ring permaneceu estável durante todos os períodos testados e apresentou valores de força de retenção significativamente menores do que os sistemas Mini Ball e Equator. O sistema Mini Ball apresentou um aumento significativo na força de retenção após o teste mecânico (controle = 21,04 ± 3,29N; 5500 ciclos = 24,01 ± 3,30N). O sistema Equator apresentou uma diminuição significativa na força de retenção após cada período testado, mas os valores eram maiores do que os outros sistemas. O tipo de sistema de encaixe influenciou na força de retenção de diferentes maneiras após testes mecânicos. O sistema do Equador exibiu os maiores valores de força de retenção. As matrizes dos sistemas Mini Ball e Equator produziram deformação e desgaste nas superfícies sem ruptura dos anéis de poliamida.


Asunto(s)
Humanos , Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Ajuste de Precisión de Prótesis , Saliva Artificial , Resistencia a la Tracción , Ensayo de Materiales , Análisis del Estrés Dental
14.
PLoS One ; 13(10): e0203951, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30304005

RESUMEN

OBJECTIVES: To verify whether the Ultra Corega Cream and Corega Strip Denture Adhesive adhesives interfere in the microbial adhesion and biofilm formation by Candida albicans and Lactobacillus casei in single- and mixed-species settings, and observe whether synergistic or antagonistic relationships between these species occur. METHODS: Specimens made from heat-polymerized acrylic resin (Lucitone 550) were fabricated (n = 144) with a circular shape and standardized roughness (3.0 µm ±0.3 Ra) and were divided into three groups: Without Adhesive (WA), with Ultra Corega Cream adhesive (CA) and Corega Strips adhesive (SA). These groups were divided into three subgroups each: C. albicans single-species, L. casei single-species and C. albicans with L. casei (mixed-species). Microbial adhesion and biofilm formation assays were performed in duplicate at four distinct experimental times (n = 8 per experimental condition). The amount of each microorganism on the surfaces of the specimens was observed by counting of the Colony Forming Units (CFU) per substrate. Additional specimens were characterized by Scanning Electron Microscopy (SEM), with 18 specimens being used in this analysis (n = 18), 2 per experimental condition (n = 2). Two-way ANOVA and Tukey's test for multiple comparisons were employed, using α≤0.05. RESULTS: L. casei (mixed-species) adhered more on the WA substrate than the CA, while C. albicans (single- and mixed-species) adhered more on the SA. C. albicans, both single- and mixed-species adhered more than the L. casei (single- and mixed-species), regardless of the substrate. L. casei (single-species) formed more biofilm on the WA, but in its mixed cultivation, it had no difference of growth among the tested situations. C. albicans (single- and mixed-species) formed more biofilm on the SA than the CA, and the fungus formed more biofilm when compared to L. casei. In general, whenever a species was compared in its single- and mixed-species situation, no statistically significant difference was observed. SEM of biofilm formation assays demonstrated that L. casei single-species WA formed more biofilm than when the adhesives tested were used, and C. albicans (both single- and mixed-species) formed more biofilm on the SA than on the CA. CONCLUSIONS: (1) The two denture adhesives tested increased the adhesion of C. albicans but not of L. casei; (2) biofilm formation by C. albicans (single- and mixed-species) was increased on the SA; (3) Relations of synergism or antagonism was not observed between the two microorganisms studied.


Asunto(s)
Adhesión Bacteriana/efectos de los fármacos , Biopelículas/efectos de los fármacos , Cementos Dentales/farmacología , Retención de Dentadura/métodos , Biopelículas/crecimiento & desarrollo , Candida albicans/efectos de los fármacos , Candida albicans/fisiología , Recuento de Colonia Microbiana , Dentadura Completa , Lacticaseibacillus casei/efectos de los fármacos , Lacticaseibacillus casei/fisiología , Microscopía Electrónica de Rastreo , Especificidad de la Especie , Propiedades de Superficie
15.
J Appl Oral Sci ; 26: e20160628, 2018 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-30304120

RESUMEN

OBJECTIVE: There is a lack of clinical evidence on mandibular overdentures (MOD) supported by a single implant. To compare patient satisfaction and masticatory performance in MOD supported by one versus two implants in a two-group parallel randomized clinical trial. MATERIAL AND METHODS: Twenty-one patients wearing new maxillary and mandibular complete dentures (CDs) were randomly divided to receive one (GI, n = 11) or two (GII, n = 10) implants in the mandibular arch. Four months after implant placement, o-ring abutments were installed in the implants, and matrix attachments were placed in the lower complete dentures. Patient satisfaction with their dentures and masticatory performance were compared at baseline, 3, 6, and 12 months after the procedure. Data on patient satisfaction were analyzed using the Friedman test and the Mann-Whitney U test. Data on masticatory performance were analyzed using one-way repeated measures analysis of variance (ANOVA) and Student's t test (α=0.05). RESULTS: Both groups exhibited a significant increase in overall patient satisfaction in all periods evaluated (p<0.05), except for GI after 12 months, which had values similar to baseline (p=0.74). Satisfaction levels of GI and GII were similar at baseline, 3 and 6 months, but GII showed higher satisfaction levels (p=0.01) than GI at 12 months. GI and GII exhibited a significant increase (p<0.05) in masticatory performance for all periods relative to baseline. However, GII had higher masticatory performance with dentures than GI, regardless of the period (p<0.05). CONCLUSION: MOD supported by two implants demonstrated better patient satisfaction in the follow-up at 12 months and better masticatory performance than MOD supported by one implant.


Asunto(s)
Prótesis Dental de Soporte Implantado/métodos , Dentadura Completa Inferior , Prótesis de Recubrimiento , Mandíbula/fisiopatología , Mandíbula/cirugía , Masticación/fisiología , Satisfacción del Paciente , Anciano , Análisis de Varianza , Retención de Dentadura , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
16.
Rev. odontol. UNESP (Online) ; 47(3): 143-148, maio-jun. 2018. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-961516

RESUMEN

Introduction: Temporomandibular disorders (TMD) can compromise masticatory performance due to the presence of pain, muscular dysfunction and limitation of mandibular movements. Substantial improvements in TMD pain can be achieved through therapeutic approaches including education and self-care. Objective: The aim of the present study was to investigate the impact of these treatment modalities in the masticatory performance of women with painful TMD. Material and method: Fifty-two women were randomly divided into three groups: Control Group (CG); Education Group (received education about TMD) (EG); Self-Care and Education Group (received education about TMD and instructions self-care therapies) (SEG). The education instructions about TMD and self-care therapies were transmitted through a video and printed illustrative material. The masticatory performance was evaluated through the sieves method ​​with natural tested foods in the evaluation periods: baseline evaluation, 30 days after and 60 days of follow-up. Data were analyzed and used with a one-way ANOVA parametric test for mean comparison of CG, EG and SEG groups (α = 0.05). Result: The masticatory performance of the participants was similar, irrespective of the proposed treatments, at baseline (p=.604), 30 days (p=.450) and 60 days (p=.669). Conclusions: The results indicated that treatment with educational and self-care therapies over a period of 60 days had no impact on the masticatory performance of women with painful TMD.


Introdução: As disfunções temporomandibulares (DTM) podem comprometer a capacidade mastigatória devido à presença de dor, disfunção muscular e limitação dos movimentos mandibulares. Melhorias substanciais da dor relacionada à DTM podem ser alcançadas através de abordagens terapêuticas incluindo a educação e os autocuidados. Objetivo: O objetivo do presente estudo foi investigar o impacto dessas modalidades de tratamento no desempenho mastigatório de mulheres com DTM dolorosa. Material e método: Cinquenta e duas mulheres foram divididas aleatoriamente em três grupos: Grupo Controle (CG); Grupo Educação (receberam instruções sobre DTM) (EG); Grupo de Autocuidado e Educação (receberam instruções sobre DTM e instruções sobre terapias de autocuidado) (SEG). As instruções de educação sobre DTM e terapias de autocuidado foram transmitidas através de vídeo e material ilustrativo impresso. O desempenho mastigatório foi avaliado através do método dos tamises com alimentos testes naturais nos períodos de avaliação: atendimento inicial, 30 dias após e ao fim de 60 dias de acompanhamento. Os dados obtidos, em porcentagem, foram analisados e foi utilizado o teste paramétrico ANOVA one-way para comparação das médias dos grupos CG, EG e SEG (α= 0,05). Resultado: O desempenho mastigatório dos participantes foi semelhante, independentemente dos tratamentos, no atendimento inicial (p=0,604), após 30 dias (p=0,450) e após 60 dias (p=0,669). Conclusão: Os resultados indicam que o tratamento com terapias educativas e de autocuidado durante um período de 60 dias não teve impacto no desempenho mastigatório das mulheres com DTM dolorosa.


Asunto(s)
Humanos , Femenino , Autocuidado , Mujeres , Trastornos de la Articulación Temporomandibular , Síndrome de la Disfunción de Articulación Temporomandibular , Análisis de Varianza , Masticación
17.
J Prosthet Dent ; 119(3): 404-408, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28689905

RESUMEN

STATEMENT OF PROBLEM: Although the cytotoxicity of denture adhesives has been widely assessed, data on the release of proinflammatory cytokines from oral epithelial cells are still scarce. PURPOSE: The purpose of this in vitro study was to evaluate the proinflammatory cytokines interleukin (IL) 1ß, IL-6, and tumor necrosis factor α (TNF-α) released from human oral keratinocytes after exposure to denture adhesives. MATERIAL AND METHODS: Eluates of the Ultra Corega cream, Corega powder Fixador Ultra, and Corega strip denture adhesives were created at 1% wt/vol after 24 hours of exposure in a Dulbecco modified Eagle medium culture. The release of IL-1ß, IL-6, and TNF-α was measured using a sandwich enzyme-linked immunosorbent assay after the oral epithelial cells (NOK-SI) had been exposed to the eluates for 3, 6, and 24 hours (n=6). RESULTS: IL-1ß release from the strip was higher at 3 hours compared with the control (Bonferroni post hoc test, P=.016). IL-6 releases from the cream and powder denture adhesives at 6 and 24 hours were higher than for the controls (Bonferroni post hoc test, P<.05). TNF-α release was not detectable in some groups and periods. CONCLUSIONS: In long periods, denture adhesive strips do not induce any change on cytokine release from human oral keratinocytes.


Asunto(s)
Citocinas/biosíntesis , Cementos Dentales , Retención de Dentadura , Queratinocitos/metabolismo , Mucosa Bucal/citología , Células Cultivadas , Humanos
18.
J Oral Implantol ; 43(4): 297-301, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28628350

RESUMEN

The lack of compatible prosthetic components can be a complication during oral rehabilitation using outdated implants. The aim of the present clinical report was to describe an alternative technique for the fabrication of a maxillary implant-supported overdenture in a patient with 20-year-old dental implants using castable spherical patterns and ball attachments. The patient had been wearing a relined bar/clip overdenture in the mandible on 4 external-hexagon dental implants and a relined complete denture in the maxilla on 4 internal-hexagon implants due to abutment screw fracture inside of the implants, losing the attachment system. The remaining maxillary dental implants did not possess attachments compatible with current systems due to configuration changes by the manufacturer in the dental implant's platform and the components over time. Therefore, castable spherical patterns and cast ball attachments were used to fabricate a maxillary implant-supported overdenture. The mandible rehabilitation was performed using 4 osseointegrated dental implants with a fixed implant-supported prosthesis. The use of cast ball attachments on the maxillary dental implants avoided invasive procedures on the remaining implants. Considering the lack of available compatible prosthetic components for the osseointegrated implants, this technique was considered a viable and satisfactory treatment option.


Asunto(s)
Prótesis Dental de Soporte Implantado/instrumentación , Prótesis Dental de Soporte Implantado/métodos , Retención de Dentadura/métodos , Prótesis de Recubrimiento , Arcada Edéntula/cirugía , Diseño de Dentadura , Humanos , Mandíbula/cirugía , Maxilar/cirugía
19.
Rev. odontol. UNESP (Online) ; 45(4): 195-200, July-Aug. 2016. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-795233

RESUMEN

Introduction: The staining of artificial teeth can be related to the acrylic resin abrasion caused by brushing, resulting in higher deposition of dyes from the beverage, and consequently higher aesthetic damage. Objective: The aim of this in vitro study was to evaluate methods for removal of stains from acrylic denture teeth using spectrophotometric analysis. Material and method: Artificial teeth were divided into twelve groups (n=10) according to the type of treatment (re-polishing - Re or immersion in Corega Tabs - Sp), staining solutions, coffee (Cf) and Coca-Cola® (Cc) or water (W) and with/without toothbrushing (B). The Sp specimens were submitted to seven immersion cycles (5 min each). The Re specimens were polished with pumice stone followed by Spain white paste. Color differences (ΔE) were captured by a spectrophotometer: T0 (baseline), T1 (after brushing/immersion in solutions) and T2 (after Re or Sp). Result: Statistically significant color change between T1 and T2 (paired T-test; α =.05) was observed for the group CfSp (p=.032); and for the groups BWRe (p=.000), BCfRe (p=.049) and CcRe (p=.042). Higher color changes were observed for the specimens submitted to toothbrushing (ANOVA two way; p<.001). Conclusion: It could be concluded that the immersion in sodium perborate (Corega Tabs) can be used for removal of coffee stains from denture teeth, and re-polishing for removal of Coca-Cola® stains. Still, toothbrushing produced greater color changes on denture teeth, regardless of the immersion solution.


Introdução: O manchamento dos dentes artificiais pode estar relacionado à abrasão da resina acrílica provocada pela escovação, resultando na maior deposição de corantes provenientes de bebidas, e consequentemente maior prejuízo estético. Objetivo: O objetivo do presente estudo foi avaliar métodos de remoção de manchas extrínsecas por meio de analise com espectofotômetro. Material e método: Dentes artificiais foram divididos em 12 grupos (n=10), de acordo com o tipo de tratamento (repolimento – Re ou imersão em perborato de sódio, Corega Tabs – Sp), tipo de solução de manchamento, café (Cf) ou Coca-Cola® (Cc) ou água (W) e com/sem escovação (B). Os métodos de remoção de manchas propostos (Re e Sp) foram realizados de acordo com protocolos pré-estabelecidos. Os espécimes Sp foram submetidos a 7 ciclos de imersão (5 minutos cada). O repolimento foi realizado com pastas de pedra pomes e branco de espanha, utilizando escovas de cerdas macias e rodas de feltro. As leituras de estabilidade de cor (ΔE) foram realizadas por meio de um espectrofotômetro: T0 (baseline), T1 (após escovação/imersão em bebidas), e T2 (após Re ou Sp). Resultado: Alterações de cor entre T1 e T2 (teste T pareado; α=0,05) foram observadas para o grupo CfSp (p=.032); e para os grupos BWRe (p=.000), BCfRe (p=.049) e CcRe (p=.042). Os dentes artificiais submetidos à escovação mostraram maior alteração de cor (ANOVA 2 fatores; p<0,001). Conclusão: Conclui-se que a imersão em perborato de sódio (Corega Tabs) pode ser utilizada para remoção de manchas de café e o repolimento para remoção de manchas de Coca-Cola®. Ainda, a escovação produziu as maiores alterações de cor nos dentes artificiais, independentemente da solução de imersão.


Asunto(s)
Diente Artificial , Cepillado Dental , Resinas Acrílicas , Técnicas In Vitro , Color , Dentadura Completa , Estética Dental , Abrasión de los Dientes , Bebidas , Espectrofotómetros , Café , Colorantes
20.
J Prosthet Dent ; 116(5): 749-755, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27236596

RESUMEN

STATEMENT OF PROBLEM: Limited mandibular movements are one of the most important signs of temporomandibular disorders (TMDs) and may cause functional difficulties. PURPOSE: The purpose of this double-blind, randomized clinical trial was to evaluate the effect of treatment with only educational or education associated with self-care therapies on the pattern of mandibular movements of women with chronic painful TMDs. MATERIAL AND METHODS: Forty-two women were selected and randomly divided into 3 groups, control group (CG, n=13), education group (EG, n=16), and education and self-care group (ESG, n=13), according to the sequence of treatment they received. A kinesiograph device recorded mandibular movements during maximum mouth opening and mastication at baseline (T0) and at 30-day (T1) and 60-day (T2) follow-up. Kinesiographic data were statistically analyzed using 1-way ANOVA, followed by the Bonferroni test for multiple comparisons of means (α=.05). RESULTS: The ESG group demonstrated an improvement in the maximum vertical opening (MVO= 5.1 ±3.4 mm; P=.012) and anteroposterior mandibular movement (MAM) during maximum opening (7.4 ±9.5; P=.019), significantly higher than that of the EG (MVO=1.8 ±3.5 mm; MAM=0.8 ±5.0 mm) and the CG (MVO=0.9 ±3.8 mm; MAM=0.8 ±4.4 mm) after 30 days of follow-up. Moreover, at T1, vertical mandibular movement during mastication was significantly higher in the ESG group (17.4 ±1.7 mm) than in the EG group (15.0 ±2.8, P=.027). No significant differences were found between the women who received treatment with educational and self-care therapies for 60 days and the women who received this treatment for 30 days. CONCLUSIONS: In the short-term, education and self-care treatment positively influenced the mandibular movement pattern of women with chronic painful TMDs.


Asunto(s)
Educación del Paciente como Asunto , Autocuidado , Trastornos de la Articulación Temporomandibular/terapia , Adulto , Método Doble Ciego , Femenino , Humanos , Mandíbula , Masticación , Movimiento , Rango del Movimiento Articular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...